USA & Canada · Licensed Engineering Review

Specialty Systems PE Stamping Services for EV, DAS/BDA, Telecom & Modular Equipment.

Some projects do not fit the standard permit checklist. A fire marshal asks for an emergency responder radio system. A utility wants stamped drawings for a skid-mounted switchgear building. A telecom carrier needs a rooftop installation certified. Reviewers for these projects often have no template, so they ask for an engineer’s seal.

Licensed PE Stamping provides specialty systems PE stamping services across the USA and Canada. Our licensed engineers review the design, check it against the codes and standards that apply, and deliver sealed documents ready for the authority having jurisdiction (AHJ) and utility.

More than one discipline. One complete installation.

A specialty system is any installation that combines engineering disciplines, uses non-standard equipment, or falls under codes beyond the usual building set.

These projects often need electrical, structural and sometimes mechanical review together. A single missing piece can hold up approval for the whole system.a

Scope the installation. Review the whole package.

Explore the engineering documentation your system may need for AHJ, utility or owner review.

EV Charging Station PE Stamp

Charging stations look simple on the outside, but plan reviewers and utilities check several things behind them: available service capacity, load management, equipment ratings and the structural support for pedestals and canopies.

We support EV charging projects with:

  • Service capacity and load calculations
  • Single-line diagrams and circuit design under NEC Article 625
  • Load management and power sharing documentation
  • Foundation and anchorage design for chargers and canopies
  • Utility upgrade and transformer coordination documents
  • Accessibility and site layout input

Public Safety DAS and BDA PE Stamp

Many fire codes require buildings to provide reliable radio coverage for first responders. When coverage inside the building is weak, the building owner usually has to install a distributed antenna system (DAS) or bi-directional amplifier (BDA), sometimes called an emergency responder radio coverage system.

Fire departments typically want to see:

  • A signal strength test and coverage design
  • Antenna layouts and riser diagrams
  • Power supply and battery backup calculations
  • Equipment locations, labeling and enclosure details
  • Structural details for mounting and anchoring equipment
  • Documentation matching the adopted fire code and local amendments

Telecom Tower and Rooftop Site PE Stamp

Telecom installations add loads to towers, monopoles and rooftops, and carriers and landlords want proof the structure can handle them.

Our engineers support:

  • Structural review for added antennas and equipment
  • Rooftop and equipment platform design
  • Equipment shelter and cabinet anchorage
  • Electrical power and grounding documentation
  • Permit drawing review for site modifications

E-House and Modular Electrical Building PE Stamp

An E-house is a prefabricated building that holds switchgear, controls and related equipment, built off site and shipped complete. The permit still needs documents showing it is safe where it sits.

We support:

  • Electrical single-line diagrams and equipment layouts
  • Structural design of the enclosure, skids and lifting points
  • Foundation and anchorage design
  • Wind and seismic checks for installation location
  • Documentation for AHJ and utility review

Containerized Substation and Skid-Mounted Equipment

Containerized and skid-mounted equipment moves a lot of work into the factory, but approval depends on documents that match the final installation.

We can prepare or review:

  • Equipment layouts and electrical diagrams
  • Structural and anchorage calculations
  • Pad or foundation design
  • Transport and lifting considerations where required
  • Interconnection documentation for the utility

Control Panel and Industrial Equipment PE Stamp

Some jurisdictions and customers want an engineer to certify custom control panels and industrial equipment installations.

We review:

  • Panel layouts and wiring diagrams
  • Component ratings and interrupting capacity
  • Short-circuit current ratings and labeling
  • Nameplate data and listing information
  • Installation drawings and field connection details

The missing detail can hold up the whole system.

We ask for the right information at the start so these issues come up during review, not after submission.

  • ↗
    The AHJ has no standard checklist, so comments arrive one at a time
  • ↗
    Electrical and structural documents are prepared separately and do not match
  • ↗
    Equipment manufacturer data is missing or incomplete
  • ↗
    Utility requirements are discovered after drawings are done
  • ↗
    Load calculations do not account for future expansion
  • ↗
    Anchorage details are missing for equipment that sits on roofs or pads
  • ↗
    The design was done under a different code edition than the AHJ adopted

From system description to coordinated, sealed documents.

Describe the system

Tell us what is being installed, where, and which authority is reviewing it. Send any drawings, equipment data and comment letters to info@licensedpestamping.com.

Get a scoped quote

Within 12 hours you receive the scope, price and timeline, including which disciplines are involved.

Coordinated engineering review

Our engineers review electrical, structural and related details together so the package is consistent.

Receive sealed documents

Signed and sealed drawings and calculations are delivered digitally. If the AHJ or utility comments, we help you respond.

Tell us what’s being installed. And who will review it.

  • Project address and the authority that will review it
  • Equipment list and manufacturer data sheets
  • Existing or draft drawings
  • Utility or fire department requirements
  • RF design or coverage test results (for DAS/BDA)
  • Site photos and structural details (for rooftop or tower work)
  • Prior comments from the reviewer

Your system. Your site. Your authority.

Equipment data, drawings and the reviewer’s requirements help us define the disciplines involved and the scope of the engineering package. Tell us what you are installing and who is reviewing it. You will receive a scope, price and timeline within 12 hours.

Local requirements. The right licensed engineers.

We provide specialty systems PE stamping services for projects in the United States and Canada.

PE & P.Eng. review

Each project is assigned to an engineer licensed in the state, province or territory where it will be built, since the seal is only valid in that jurisdiction.

Confirm requirements early

Because specialty systems often fall under local amendments, we confirm the adopted codes at the start of every project.

Frequently Asked Question

A distributed antenna system or bi-directional amplifier boosts radio signals inside a building so first responders can communicate. Many fire codes require one when coverage is below the required level.

It depends on the size and the jurisdiction. Larger commercial installations, service upgrades and canopy structures commonly need stamped drawings, while a single residential charger often does not.

An E-house is a prefabricated building that houses electrical equipment such as switchgear and controls. It is built off site and delivered to the project.

We can review the installation, anchorage and electrical connections for the site. Whether we can certify the equipment itself depends on the equipment and the authority’s requirements, so ask us at the quote stage.

Yes, in most cases. Added antennas and equipment change the loads on the tower or roof, and carriers and landlords generally require analysis.

Simple installations can take a few business days. Multi-discipline systems take longer. Your quote includes an estimated timeline.

Yes, through engineers licensed as P.Eng. in the relevant province.

Send us the comments. We will update the documents where needed and help you resubmit.

Request specialty systems PE stamping services.

Send your project details for a clear quote within 12 hours.