USA & Canada · Licensed Engineering Review
The numbers checked. The documents coordinated. An electrical permit reviewer reads your drawings looking for numbers that do not add up a service sized below the calculated load, a breaker that cannot interrupt the available fault current, a feeder that does not match the panel schedule. Licensed PE stamp tells the reviewer those numbers were checked by someone accountable for them. We prepare, review and seal electrical documents for permits and utility approval in the USA and Canada.
A stamp is the last step. Before it, the engineer works through the design in a set order. If any step fails, you get a written list of corrections instead of a stamp.
Connected and demand loads are totaled using the method in NEC Article 220 (or the Canadian Electrical Code equivalent), which sets the minimum service size.
Conductors, conduit and overcurrent devices are sized against that load, with temperature, ambient and terminal ratings applied.
The engineer confirms every breaker and switchboard has an interrupting rating above the fault current at its location, and that required labeling is on the drawings.
Electrodes, bonding jumpers and equipment grounding conductors are checked against NEC Article 250.
Long runs are verified so equipment gets stable voltage.
The one-line, panel schedules, riser and plan sheets must all agree. Mismatches between them are among the most common causes of comments.
Electrical documentation for service upgrades, new construction, added equipment and utility review.
One-line drawings showing utility service, metering, main disconnect, switchboards, panels, transformers, generators and the ratings of each device. Utilities and plan reviewers use these to verify safety and coordination.
Residential, commercial and industrial load calculations supporting service upgrades, new tenants and added equipment. Without one, many jurisdictions will not approve a larger service.
Circuit-by-circuit schedules with breaker sizes, wire sizes, load descriptions and phase balancing, matched to the one-line and calculation.
Fault current calculations and device coordination information where the project, utility or authority requires them.
Fixture layouts, receptacle circuits, emergency lighting and controls, with energy code compliance documentation where it applies.
Device layouts, riser diagrams, battery and circuit calculations prepared to NFPA 72 and local fire authority requirements.
Design for emergency (NEC 700), legally required standby (701) and optional standby (702) systems, including transfer switches, feeder sizing and fuel or pad coordination.
Service capacity checks, load management strategy and circuit design under NEC Article 625 for residential, commercial and fleet charging.
Review and certification of control panel assemblies and industrial equipment installations, including nameplate data and interrupting ratings.
These issues come up repeatedly in plan review, and we check for each of them. Catching these before submission is usually faster than responding to rejection comments.
PE Stamping requirements depend on the project scope, local authority and utility.
Many standard residential jobs do not need a PE stamp. They commonly do when the service is large, the building is multi-family, or the project includes generators, EV charging or solar with battery storage. Requirements depend on the local authority.
Stamped drawings are far more likely to be required. Expect requests for full one-lines, load calculations, panel schedules, emergency systems and fault current data, and sometimes coordination studies.
For a panel upgrade, clear photos of the existing panel, meter and main disconnect often save a full round of questions.
Small jobs, such as a service upgrade with a load calculation and one-line, can often be completed in a few business days. Commercial packages with multiple panels, generators or fire alarm take longer. Your quote includes an estimated timeline before work begins.
Often no for a standard single-family home, but it depends on the jurisdiction and utility. A load calculation and one-line are frequently requested even when a stamp is not.
The load calculation determines how much capacity the building needs. The panel schedule lists what each circuit serves and how it is protected. Reviewers expect both to agree.
Breakers must be able to interrupt the maximum fault current at their location. If they cannot, they can fail dangerously. NEC 110.24 requires available fault current to be documented on certain service equipment.
In many cases, yes, after review. If ratings or calculations do not support the design, you receive a list of corrections.
Often for commercial and emergency or legally required standby systems. Residential portable and small standby units are treated differently by jurisdiction.
Canadian projects follow the Canadian Electrical Code and provincial rules, and are handled by engineers licensed as P.Eng. in the relevant province.
Send your project details for a clear quote within 12 hours.
Professional engineering review and certification. Supporting projects across the USA and Canada.